YH-DWEH001
Veterinary ventilator or veterinary respiratory support system, is a medical device used to assist animals in maintaining normal respiratory function. These ventilators are designed to provide mechanical support when an animal has difficulty breathing due to physical injury, surgery or other reasons, ensuring oxygen supply and carbon dioxide removal to maintain gas exchange and sustain life. Vet ventilators can be used on a variety of animals, including dogs, cats, horses, cattle, pigs, birds, mice, rats, etc.
1. International standard interface, can match any international standard pet anesthesia machine.
2. Pressure, volume, autonomous and other breathing modes.
3. With end-expiratory pressure PEEP monitoring.
4. Pressure difference flow rate monitoring, monitoring flow rate more accurately.
5. Just set animal weight and other parameters are automatically calculated.
6. With suffocation alarm function.
7. Automatically set alarm parameters independently according to different weights.
8. Equipped with a cooling fan system to reduce the machine temperature and allow the ventilator to be used for a long time.
YOHUVET Animal Medical provides customers with customized products, multi-dimensional product portfolios and overall solutions. According to the customer's space environment, financial status and other factors, it is configured according to the needs to meet the customer's needs in different application scenarios and ensure its reliability and safety in use.
YOHUVET Animal Medical integrates R&D, design, production, sales and service. Global customers benefit from our long-term experience in international OEM/ODM business.We can always meet the different needs of customers and guarantee their interests, making us a trustworthy strategic partner.
Ventilation parameters | YH-DWEH001 | Alarm parameters | YH-DWEH001 |
Tidal volume | 20~1500mL | Upper pressure limit | 0~60cmH20 |
Respiratory frequency | 1~150bpm | Lower pressure limit | 0~60cmH20 |
Inspiration-to-expiration ratio | 9.9:1~1:9.9 | Upper limit of tidal volume | 0~1500mL |
Breath holding time | 0~50% | Lower limit of tidal volume | 0~1500mL |
Flow rate trigger sensitivity | 0.5 ~ 20L/min, OFF | Ventilation upper limit | 0~40L/min |
Pressure trigger sensitivity | -1~-20 cmH20, OFF | Ventilation lower limit | 0~40L/min |
End expiratory pressure | 3~20 cmH20, OFF | Upper limit of oxygen concentration | 15~100% |
Inspiratory time | 0.1~12s | Lower limit of oxygen concentration | 15~100% |